CLF10 sc and CLT10 sc Free and Total Reagentless Chlorine Analyzer
þ
ǰ
īװ : м > > Chlorine
Maker : HACH
 
ǰ
Specifications
Chlorine Sensor
Measurement Range : 0 to 10 ppm
 
Lower Limit of Detection (LOD) : 30 ppb (0.03 ppm) or lower
 
Limit of Quantitation (LOQ) : 90 ppb (0.09 ppm) or lower
 
Resolution : 0.001 ppm (1 ppb)
 
Accuracy : Free Chlorine:
                       3% of the reference test** (DPD) at constant pH less than 7.2 (0.2 pH  unit)
                       10% of the reference test** (DPD) at stable pH less than 8.5 (0.5 pH unit from
                    the pH  at calibration)
                       Total Chlorine:
                       20% of the reference test** (DPD) at stable pH greater than 8.5
 
Repeatability : 30 ppb or 3%, whichever is greater
 
Response Time : Free Chlorine:
                             140 seconds or less for 90% change (T90) at a stable temperature and pH
                                             Total Chlorine:
                             100 seconds or less for 90% change (T90) at a stable temperature and pH
 
Sampling Time : Continuous
 
Interferences : Free Chlorine: Monochloramine, chlorine dioxide, ozone, and chalk 
                           deposits
                                         Total Chlorine: Chlorine dioxide, ozone, and chalk deposits
 
Pressure Limit : 0.5 bar, no pressure impulses and/or vibrations
 
Sample Flow Rate : 30 to 50 L/hour (7.9 to 13.2 gal/hour), Optimal is 40 L/hour 
                                          (10.5 gal/hour)
 
Sample pH : 4-9
 
Sample Temperature (compensated for fluctuations) : 5 to 45C (41 to 113F)
 
Temperature Compensation : Internal temperature sensor
 
Storage Temperature : Sensor: 0 to 50C (32 to 122F) dry, without electrolyte
                                                            Electrolyte: 15 to 25C (59 to 77F)
 
Power Requirements : 12 Vdc, 30 mA maximum (supplied by controller)
 
Dimensions (sensor only) : 195 mm (7.68 in.)/25 mm (0.98 in.) (length/diameter)
 
Cable Length : 1 m (between gateways and sc-controller)
 
Cable Connection : 5 pin, M12 connector
 
Measurement Method : Reagentless, electrochemical, three-electrode amperometric
                                                 system
 
Calibration Methods : 1-point or 2-point (zero and slope) calibration
 
Material : Corrosion-resistant materials, fully-submersible (stainless steel, PVC, silicon
                 rubber and polycarbonate)
 
Warranty : 1-year warranty on the electrode body, includes the electronics
 
Panel (including SS Panel, Gateway, Chlorine Sensor Flow Cell, pH Sensor Flow Cell)
Operating Temperature : 0 to 45C (32 to 113F)
 
Storage Temperature (panel only) : -20 to 60C (-4 to 149F)
 
Power Requirements : 12 Vdc 10%, at 100 mA maximum (supplied by sc controller)
 
Mounting: Flat, vertical surface
 
Connections : Sample Line: 1/4-inch OD
                                    Drain Line (pH Flow Cell Outlet): 1/2-inch ID
 
Panel Dimensions : Length 482.6mm (19 in.) x Width 495.3mm (19.5 in.) x Depth 151.2mm
                                 (5.95 in.) (with panel-mounted components)
 
Weight : Approximately 5.5 kg (12 lbs) (panel and empty panel-mounted components only)
               Controller Platform : sc controller models
 
Complete Analyzer (Panel + Sensor)
Waterproof Rating : Current rating for Sc100/1000/200 controllers, gateway, and sensors
                                       IP65 (NEMA 4X)
 
Certification : CE / ETL, EMC
 
Shipping Weight : Approximately 9.1 kg (20 lbs)